Fusion Architectures and the JDL Model

Five sensors watch one car. Where you combine their readings decides how much data crosses the wires and whether one dead box blinds the system. It also decides whether the fused confidence is honest. Raw data needs about 31,000 times the bandwidth of tracks.

Pick an architecture. Then fail a box with the buttons under the picture and read the verdict. Then we build, piece by piece, the JDL levels, Dasarathy's modes, each architecture and the double-counting trap.

You need Lesson 1 and one idea from it: a precise sensor deserves more weight. We build the rest from zero.

Lesson 2 of the series Sensor Fusion: Classical to Modern. The vocabulary comes from four sources. Steinberg, Bowman and White (1999) revised the JDL model. Dasarathy (1997) named the data, feature and decision modes. Durrant-Whyte, Rao and Hu (1990) built decentralized fusion, and Castanedo (2013) surveys it all. The devices and toy numbers are our own.

Fuse five sensors three ways

Fail:

An illustrative toy. The sensor variances are 4, 9, 16, 6 and 5 m². A raw link carries 100 Mbit/s and a track link 20 kbit/s. In decentralized mode the peers add each other's estimates with no guard, so their confidence grows with each round of gossip.

Chapter 0

Where Does the Fusing Happen?

Count what crosses the wire, and see why the place you fuse is a design choice with a price

A car carries three cameras and five radars. Many times a second, it must turn all eight streams into one sentence: a pedestrian, 18 m ahead, moving left, brake.

Lesson 1 asked how two sensors relate. This lesson asks where the combining runs, and who decides. That choice is the fusion architecture: the place where readings meet, and what each sensor sends to get there. Three forces decide it.

ForceThe questionHow it fails
BandwidthCan the wires carry what the sensors send?The bus overflows and frames drop.
Fault toleranceWhat happens when one box dies?The whole system goes dark.
HonestyDoes the fused confidence match the real error?The estimate is sure and wrong.

Bandwidth fails first, so count it. Call the size of one message b bytes, and the number of messages each second f.

Say it aloud

R equals b times f times eight.

R
R the bit rate one stream puts on the wire, in bits per second.
b
b the bytes in one message: a camera frame, or a track.
f
f the messages sent each second, in hertz.
8
times eight the bits in one byte.
In plain words

Multiply the message size b by the messages per second f. Multiply by 8 to turn bytes into bits. The result is R.

With numbers

A raw 1080p frame is 1920 × 1080 × 3 = 6,220,800 bytes. At f = 30, R = 6,220,800 × 30 × 8 ≈ 1.49 Gbit/s. A 50-byte track at 50 Hz is 50 × 50 × 8 = 20 kbit/s.

Load the car's bus

The bar is the total load of all eight sensors, on a scale where each step is ten times the last. The dashed lines are two networks. Choose what the sensors send.

Illustrative rates. A raw camera is 1.49 Gbit/s and a raw radar 100 Mbit/s. A feature message is 2 KB at 30 Hz for a camera and 1 KB at 20 Hz for a radar. A track is 50 bytes at 50 Hz. The dashed lines put CAN FD at about 5 Mbit/s and automotive Ethernet at 1 Gbit/s.

Raw data from all eight sensors is about 5 Gbit/s. Eight tracks are 160 kbit/s, about 31,000 times less. The raw load is five times a 1 Gbit/s automotive Ethernet link. The tracks fit on a CAN FD bus with room to spare.

Symptom: frames drop at the fuser while every sensor reports healthy.

Measure: add up R for every stream on the link and compare it with the link's rate.

Fix: send smaller things, features or tracks (Chapter 2).

The road

  1. The JDL levels: what the fusion output is about.
  2. Dasarathy's modes: what goes into a fusion block and what comes out.
  3. Centralized fusion: every raw reading in one box. The hero's first button.
  4. Distributed and decentralized: ship estimates, and add information in any order.
  5. The double-counting trap: why a peer network grows falsely sure.
  6. The architecture explorer: the hero, with every knob.
  7. Choosing an architecture: four questions and one reliability formula.
  8. Four traps: late readings, skewed clocks, hidden single points of failure.
  9. The field guide: numbers, code, links and sources.
Eight sensors each send a 50-byte track 50 times a second. What load do they put on the bus?

Chapter 1

The JDL Levels: What Are You Reasoning About?

Climb from raw signals to threats, and find the level that points the sensors

Two engineers both say they work on sensor fusion. One averages two voltage readings. The other decides whether an approaching car is a threat. They do different jobs, and a meeting between them goes nowhere.

The JDL model is a shared list of levels from the Data Fusion Group of the US Joint Directors of Laboratories. Each level names what a fusion output is a statement about. Steinberg, Bowman and White revised it in 1999 and named Level 0.

LevelThe output is aboutOne pedestrian
L0 Signalcleaned, aligned raw signalspixels and a radar return at bearing 12°
L1 Objectone thing: where, how fast, whattrack 7 at (16 m, −3 m), 1.2 m/s
L2 Situationrelations between objectstrack 7 and our car converge
L3 Impactwhat happens next, and how badcollision in 1.4 s if nobody yields
L4 Process refinementhow to sense betterpoint the radar beam at track 7

Climb the ladder

Pick a level and a system. The box under the ladder shows what that level produces.

The pedestrian and the airliner outputs are illustrative examples of each level, not logs from a real system.

Level 1 is where most of this series lives: tracking and the Kalman filter. When people say sensor fusion with no qualifier, they mean Level 1.

Level 4 sits to the side. It describes the sensing, not the world, and it acts. It points a steerable radar at the track with the largest uncertainty. That arrow back to the sensors turns the ladder into a loop.

The level also hints at the architecture. Level 0 moves pixels, so it needs a fat link or fusion next to the sensor. Level 1 tracks are small, so they suit a distributed design. Level 3 is a short list of threats for one decision maker.

Symptom: two teams argue about the best fusion method and talk past each other.

Measure: ask what each output is a statement about: signals, objects, scenes, threats or the sensing.

Fix: name the level first. Then compare methods inside one level.

A car's software outputs: "collision with the pedestrian in 1.4 s; this is the top threat." Which JDL level is that?

Chapter 2

Dasarathy's Modes: What Goes In, What Comes Out

Label every fusion block by its input and output, and pay for each step down in lost detail

JDL says how abstract an output is. Dasarathy (1997) asks a narrower question about each fusion block: what kind of thing goes in, and what kind comes out?

There are three kinds. Data is a raw measurement, such as pixels or radar returns. A feature is a descriptor taken from data, such as an edge, a box or a cluster of points. A decision is a verdict, such as "pedestrian, 0.90".

ModeIn, outExample
DAI–DAOdata in, data outmerge two LiDAR point clouds into one
DAI–FEOdata in, feature outtwo raw images become one depth map
FEI–FEOfeature in, feature outjoin camera edges and LiDAR clusters
FEI–DEOfeature in, decision outa classifier reads the joined features
DEI–DEOdecision in, decision outvote on each sensor's label

There is no decision-in, data-out mode. You cannot rebuild the pixels from the word "pedestrian". Information flows only downhill.

Walk down the staircase

Pick a mode. The arrow shows what the block takes and gives. The ruler shows what reaches the block for one frame.

Illustrative sizes for one camera and radar frame: raw data about 6 MB, a feature vector about 2 KB, a verdict about 16 bytes.

From raw data to a verdict, the message shrinks by a factor of about 375,000. That is why decision fusion makes distributed designs cheap: each node decides, then sends a few bytes.

Each step down also throws detail away. A camera says "pedestrian, 0.55". A radar says "pedestrian, 0.55". If the two are independent and the prior is even, multiply their odds: (0.55/0.45)² ≈ 1.49, a probability of 0.60. That is still a shrug.

A feature fuser would see more. Both sensors point at the same bearing, 12°, with the same motion. That match is strong evidence, and it is gone once each sensor squeezes its view into one number.

Symptom: two weak sensors that agree in detail still give a weak fused verdict.

Measure: run feature-level fusion on the same clips and compare the scores.

Fix: move the fusion one step up the staircase, if the bus allows it.

Three airspeed units each output a number. A voter takes the median. Which mode is the voter?

Chapter 3

Centralized Fusion: Every Raw Reading in One Box

Add every sensor's precision in one place, and see why one box is both the best estimate and the weakest point

Three radars measure the range to the same car, with variances 4, 9 and 16 m². In centralized fusion, every sensor sends its raw reading to one fuser, the box that combines them. The sensors decide nothing.

Lesson 1 gave each reading a vote strength. Call it the precision: one divided by the variance. Call the variance of sensor i σi² and the fused precision P.

Say it aloud

P equals the sum over i of one over sigma-i squared.

P
P the fused precision, in 1/m². One over P is the fused variance.
Σi
the sum over i one term for each sensor.
σi²
sigma-i squared the variance of sensor i, in m².
In plain words

Turn each variance σi² into a precision by dividing 1 by it. Add the precisions. The sum is P.

With numbers

P = 1/4 + 1/9 + 1/16 = 0.25 + 0.111 + 0.0625 = 0.424. The fused variance is 1/0.424 = 2.36 m², below the best sensor's 4 m².

The fused range weights each reading by its precision. Call reading i zi and its precision Pi.

Say it aloud

x-hat equals the sum over i of P-i times z-i, divided by P.

x̂
x-hat the fused range, in m.
Σi
the sum over i one term for each sensor.
Pi
P-i the precision of sensor i.
zi
z-i the reading of sensor i, in m.
P
P the sum of all precisions, from the first equation.
In plain words

Multiply each reading zi by its precision Pi. Add the products. Divide by P.

With numbers

Readings 100.2, 99.5 and 101.0 m: (25.05 + 11.06 + 6.31)/0.424 = 100.13 m. The sloppy third radar barely moves the answer.

Feed one fuser

Dots are raw readings, larger when more precise. The teal band is the fused estimate ±1σ. Add sensors, then crash the fuser.

3

Illustrative sensors: variances 4, 9, 16, 6 and 5 m², readings 100.2, 99.5, 101.0, 100.8 and 99.9 m.

No architecture beats this, because no sensor throws data away before the fuser. So centralized fusion is the yardstick. It pays three costs: raw data on the wire, all the compute in one box, and one box whose death silences every sensor.

Symptom: the fuser reboots, and every healthy sensor goes unheard.

Measure: kill each box in a test and check whether the function survives.

Fix: a second fuser in parallel (Chapter 7), or no fuser at all (Chapter 4).

Why is centralized fusion called optimal?

Chapter 4

Distributed and Decentralized: Ship Estimates, Not Data

Let each sensor track on its own, then add information in any order to reach the central answer

Make each sensor smart. The radar runs its own tracker and sends a track: its estimate and its variance, a few dozen bytes. In distributed fusion, nodes track locally and one fuser combines the tracks.

Remove the fuser too. In decentralized fusion, every node is a peer. It swaps estimates with its neighbours and keeps its own fused belief. No node is special, so no single death blinds the network.

ArchitectureWho fusesOn the wireSingle point of failure
Centralizedone fuserraw datayes, the fuser
Distributednodes, then one fusertracksyes, the fuser
Decentralizedevery peerestimates, peer to peernone

How can peers with no boss reach the central answer? Use the information form. Call a node's precision its information Y, and its estimate times its precision y.

Say it aloud

Big Y equals Y-A plus Y-B, and little y equals y-A plus y-B.

Y
big Y the fused information: the fused precision, in 1/m².
YA
Y-A node A's information, one over its variance. Y-B is the same for node B.
YB
Y-B node B's information.
y
little y the fused information vector. The fused estimate is y divided by Y.
yA
y-A node A's estimate times its information.
yB
y-B node B's estimate times its information.
In plain words

Add the two informations to get Y. Add the two weighted estimates to get y. Divide y by Y for the fused estimate.

With numbers

Radar A: 18.2 m, variance 4. Radar B: 17.6 m, variance 9. Y = 0.25 + 0.111 = 0.361 and y = 4.55 + 1.96 = 6.51. The estimate is 6.51/0.361 = 18.02 m, variance 2.77 m².

Addition does not care about order or about who adds. So peers can gossip in any order and still reach the central total, as long as every piece is independent.

Let three peers gossip

Each peer shows the information it claims and the letters of the readings it holds. Press the swaps in any order, then close the loop.

Illustrative peers with information 0.25 (A), 0.111 (B) and 0.0625 (C). A swap adds the partner's claimed total, with no record of where it came from.

Press A ↔ B, then B ↔ C. B and C reach 0.424, the central answer. Now press C ↔ A. C's total already contains A's reading, so A counts its own reading a second time.

Symptom: a peer's confidence keeps rising while no new readings arrive.

Measure: tag each contribution with its source and look for one source counted twice.

Fix: keep the source list, or use a rule that is safe without it (Chapter 5).

What is the key difference between distributed and decentralized fusion?

Chapter 5

The Double-Counting Trap

Count shared information once, and see how an echo makes a fuser sure of nothing

Two radar nodes start from the same broadcast estimate: range 100 m, variance 10 m². Call the precision of this shared common prior Pc = 0.10. Each node then adds its own independent reading, also precision 0.10.

Each node now holds precision 0.20, variance 5 m². The fuser gets PA = 0.20 and PB = 0.20 and adds them: 0.40, variance 2.5 m². That number is a lie. The distinct pieces are the prior, reading A and reading B, worth 0.30.

Say it aloud

P-honest equals P-A plus P-B, minus P-c.

Phonest
P-honest the fused precision with each piece counted once.
PA
P-A node A's precision: the prior plus its own reading.
PB
P-B node B's precision, built the same way.
Pc
P-c the precision of the shared prior, inside both nodes.
In plain words

Add PA and PB. Both contain the prior, so subtract one copy of Pc.

With numbers

0.20 + 0.20 − 0.10 = 0.30, variance 3.33 m². The naive 2.5 m² claims a third more certainty than the evidence holds.

Watch the naive fuser lie

Each bell is a fused belief; narrower means surer. Drag the shared prior up, then feed the result back.

0.10
0.10

Values are precisions, one over the variance. The covariance intersection curve uses weight 0.5. The feedback button lets the naive fuser count its own last output once more.

Press the feedback button. Each round, the fuser counts its own output again, and its precision doubles: 0.40, 0.80, 1.60. No new reading arrived. The variance falls toward zero anyway.

The fix needs Pc, and a peer mesh often cannot know it. Covariance intersection is a rule that stays safe for any correlation. Pick a weight ω between 0 and 1.

Say it aloud

Y-C-I equals omega times Y-A, plus one minus omega, times Y-B.

YCI
Y-C-I the fused information under covariance intersection.
ω
omega a weight from 0 to 1 on node A.
YA
Y-A node A's information, one over its variance.
1 − ω
one minus omega the weight left for node B.
YB
Y-B node B's information.
In plain words

Blend YA and YB with weights that sum to one, instead of adding them. YCI can never pass the larger of the two.

With numbers

With ω = 0.5: 0.5 × 0.20 + 0.5 × 0.20 = 0.20, variance 5 m². That is humble beside the honest 3.33 m², and never overconfident.

Symptom: errors land outside the claimed bounds far more often than they should.

Measure: a consistency test over many runs (Chapter 8).

Fix: subtract the shared part if you know it, use covariance intersection if you do not, and never let a fuser eat its own output.

Two nodes share a prior of precision 0.10. Each adds a reading of precision 0.10. What is the honest fused precision?

Chapter 6

The Architecture Explorer

Break one network three ways and read the cost of each choice in numbers

Here is the hero network with every knob. Fail any box, add an echo, turn on covariance intersection, and read the wire load, the survival and the honesty of the estimate.

Pick, break and read

Tap a sensor, the fuser, or a button to fail it. The bars give the wire load, the honest variance and the variance the system reports.

Fail:

The hero's toy: variances 4, 9, 16, 6 and 5 m², raw links 100 Mbit/s, track links 20 kbit/s each way. An echo doubles the reported precision once per round. In the ring, peers that add with no guard echo each other.

  1. Centralized, fail the fuser. Five healthy sensors and no estimate.
  2. Distributed, fail S2. It survives, and the wire load falls from 500 Mbit/s to 80 kbit/s.
  3. Turn on the echo. The reported variance halves each round. The honest one stays put.
  4. Decentralized, fail S1 and S3. The ring splits into two groups, and each still fuses.
  5. Turn on covariance intersection. The reported variance rises above the honest one: humble, not a lie.

No setting gives a thin bus, survival of any one failure and honest confidence for free. Decentralized fusion with covariance intersection comes closest, and it pays in sharpness.

Which architecture keeps fusing after the loss of any one box?

Chapter 7

Choosing an Architecture

Ask four questions in order, then check the reliability on paper before you build

A design lands on your desk: these sensors, this bus, this safety rule. Ask four questions in order. The first one that bites picks the architecture.

  1. Can the bus carry raw data from every sensor? If not, ship estimates.
  2. Must the function survive the loss of any one box? If so, no lone fuser: decentralize, or run two fusers.
  3. Few sensors, a short bus, and you want the best estimate? Centralize.
  4. A large system with natural parts? Build a hierarchical tree of fusers and pick each branch by its own constraint.

Then one check for every design: if estimates flow and any path loops, guard against double-counting.

SystemWhat bindsArchitectureGuard
Small dronenothing: few sensors, short buscentralizednone needed
Building, 200 roomslong links; a hub may failzone fusers that gossipcovariance intersection
30 warehouse robotsWi-Fi cannot carry 30 LiDARscentral in each robot, peers betweencovariance intersection

Question 2 has a number behind it. A centralized system works only if the fuser works and at least one sensor works. Call the fuser's reliability Rf, each sensor's Rs, and the number of sensors n.

Say it aloud

R equals R-f times, one minus, one minus R-s to the n.

R
R the chance the whole system works through a mission.
Rf
R-f the chance the fuser works.
(1 − Rs)n
one minus R-s to the n the chance that all n sensors fail; R-s is one sensor's reliability.
In plain words

Raise one sensor's failure chance, 1 − Rs, to the power n. One minus that is the chance at least one works. Multiply by Rf, because the fuser must work too.

With numbers

Rf = 0.99, Rs = 0.99, n = 5: R = 0.99 × (1 − 10−10) ≈ 0.99. Two fusers in parallel give 1 − 0.01² = 0.9999.

Count the nines

Each bar counts nines: 0.99 is two, 0.9999 is four. The dashed line is a four-nines spec. Add sensors, then add a second fuser.

0.99
0.99
5

Assumes the boxes fail independently. Real failures share power, heat and software, so treat these as upper bounds.

A tree also spreads the load. Four radars at 20 kbit/s feed two group fusers, so no link carries more than 40 kbit/s. A flat design pushes 80 kbit/s into one box.

Symptom: the spec asks for four nines, and adding sensors never gets there.

Measure: compute R with the formula. Find the box that caps it.

Fix: duplicate that box, or remove it.

A centralized system has one fuser with reliability 0.99 and ten perfect sensors. What is its reliability?

Chapter 8

Four Traps in a Real Network

Catch late readings, skewed clocks, hidden single points of failure and false confidence

Architecture bugs rarely crash. The data takes a path you did not draw, or arrives at a time you did not expect. Each trap has a test.

TrapSymptomTestFix
Double-countingerrors escape the claimed boundsconsistency testsubtract the shared part, or covariance intersection
Out-of-sequence readingthe track jumps back when a slow sensor reportscompare each timestamp with the state's timebuffer, or roll back and replay
Hidden single point of failurea "distributed" system goes dark at oncekill each box in turna second fuser, or a peer fallback
Clock skewa bias that grows with target speedmeasure the offset between node clockshardware time sync; stamp at sensing

An out-of-sequence measurement is a reading that arrives after a newer one. Both timing traps share one number. A reading that is Δt seconds old shows where the target was. Call the target's speed v.

Say it aloud

e equals v times delta-t.

e
e how far behind the target the reading points, in m.
v
v the target's speed, in m/s.
Δt
delta-t the reading's age, or the offset between two clocks, in s.
In plain words

Multiply the target's speed v by the reading's age Δt. The product e is the distance the target moved since the reading.

With numbers

A 30 ms clock offset puts a 1.5 m/s pedestrian 4.5 cm off and a 30 m/s car 0.9 m off. A camera frame 60 ms late on a 25 m/s car points 1.5 m behind it.

Deliver a late reading

The teal mark is where the car is now. The yellow mark is where the late reading says it is. Change speed and delay, then roll back.

25 m/s
60 ms

Illustrative. Rolling back means: move the state to the reading's timestamp, fuse it there, then predict forward to now.

Sensor noise does not grow with speed. A timing error does. If the error scales with speed, suspect a clock.

To catch double-counting, compare real errors with claimed ones over many runs. A calibrated fuser has about 68% of errors inside ±1σ and 95% inside ±2σ. The Chapter 5 fuser claims σ = 1.58 m when the truth is 1.83 m.

BandCalibratedNaive fuser
±1σ (±1.58 m)68%61%
±2σ (±3.16 m)95%92%

Over 1,000 frames that is about 83 escapes outside ±2σ where the claim allows 50. The formal version is the NEES test in Lesson 21.

Each sensor alone is accurate, but the fused track lags more the faster the target moves. Which trap is it?

Chapter 9

The Field Guide

Keep the terms, the numbers, the checks and the code in one place

The relationship between sensors (Lesson 1) says whether combining helps. The architecture says whether you can afford it, whether one failure kills it, and whether its confidence is honest.

TermMeaningNumber to remember
JDL levelswhat an output is about: signal, object, situation, impact, sensing5 levels, L0 to L4
Dasarathy modesinput and output kind of a fusion block6 MB to 16 bytes per frame
Centralizedraw data to one fuser; optimal; one point of failurevariances 4, 9, 16 fuse to 2.36 m²
Distributednodes track, one fuser combines tracksa track: 20 kbit/s
Decentralizedpeers add information, no fuser0.25 + 0.111 + 0.0625 = 0.424 in any order
Hierarchicala tree of fusersfan-in halves with two groups
Double-countinga shared piece counted in two estimatesnaive 0.40 against honest 0.30
Covariance intersectiona weighted blend that is never overconfident0.20, variance 5 m²
Timing errorspeed times a reading's age25 m/s × 60 ms = 1.5 m

Before you build

  1. Add up R = b × f × 8 for every link and compare it with the link.
  2. Kill each box on paper. Double or remove any box whose loss is total.
  3. Compute R = Rf × (1 − (1 − Rs)n) against the spec.
  4. Trace one reading through the graph. If it can reach a fuser by two paths, guard it.
  5. Stamp every reading at sensing, on one shared clock.
  6. Run a consistency test before you trust any reported variance.
pythondef fuse_central(readings, variances):        # every raw reading in one place
    P = sum(1.0 / v for v in variances)                 # precisions add
    x = sum(z / v for z, v in zip(readings, variances)) / P
    return x, 1.0 / P

def fuse_naive(P_A, P_B):              # wrong when A and B share a past
    return P_A + P_B

def fuse_known_common(P_A, P_B, P_c):   # exact, if you know the shared part
    return P_A + P_B - P_c

def fuse_ci(P_A, P_B, w=0.5):          # safe for any correlation
    return w * P_A + (1 - w) * P_B

fuse_central([100.2, 99.5, 101.0], [4, 9, 16])   # (100.13, 2.36)
fuse_naive(0.20, 0.20)                          # 0.40  overconfident
fuse_known_common(0.20, 0.20, 0.10)            # 0.30  honest
fuse_ci(0.20, 0.20)                             # 0.20  humble

Keep going

Sources

  1. Steinberg, A. N., Bowman, C. L., and White, F. E. "Revisions to the JDL Data Fusion Model." Proc. SPIE 3719, 1999. doi:10.1117/12.341367
  2. Dasarathy, B. V. "Sensor Fusion Potential Exploitation: Innovative Architectures and Illustrative Applications." Proceedings of the IEEE 85(1), 1997. doi:10.1109/5.554206
  3. Durrant-Whyte, H. F., Rao, B. Y. S., and Hu, H. "Toward a Fully Decentralized Architecture for Multi-Sensor Data Fusion." ICRA, 1990. doi:10.1109/ROBOT.1990.126184
  4. Castanedo, F. "A Review of Data Fusion Techniques." The Scientific World Journal, 2013. doi:10.1155/2013/704504
The takeaway. Fuse raw data in one place when the bus and the safety case allow it. Otherwise ship estimates, and count every shared piece once.
A team moved from centralized to distributed fusion and says the estimate is now cheaper and more accurate. What is the correction?

Now press Present or Teach and explain from memory: the three forces, the five JDL levels, the three architectures and the double count. Then go back to the hero, fail the fuser in each mode, and say why each verdict comes out as it does.

Sensor Fusion: Classical to Modern · Lesson 2: Fusion Architectures and the JDL Model
Lesson 1 · Lesson 3 · Back to Gleams