The Information Filter

Store how sure you are instead of how unsure, and fusing a sensor becomes one addition. Six cameras, six additions: the error ellipse shrinks from 8 m long to under 1 m, the same answer the Kalman filter gives.

Switch cameras on and off. Watch the ellipse shrink most in the direction each new camera sees well, and watch the purple stacks add up. Then we build, piece by piece, information, the update that adds, the costly predict step, and the networks that run on it.

You need what a variance is and the Kalman filter idea of Lesson 5. We build the rest from zero.

Lesson 9 of 22 in Sensor Fusion: Classical to Modern. The filter follows Thrun, Burgard and Fox, Probabilistic Robotics (2005), Chapter 3. Next: The Particle Filter.

Add cameras, add information

Illustrative toy: six cameras on a 4 m ring around the target. Each pins the target to 0.4 m across its line of sight and 2 m along it. The ellipse holds 2 standard deviations. The readings use fixed noise, so the run repeats.

Chapter 0

Twelve Cameras, One Forklift

See why many sensors need weights, and why the bookkeeping of the weights matters

A forklift crosses a warehouse. Twelve ceiling cameras watch it. Each camera reports a position with its own error. The camera overhead is good to 0.3 m, the one in the far corner only to 4 m.

A flat average treats the 4 m camera like the 0.3 m camera. Lesson 3 gave the fix: weight each reading by one over its variance. Add the cameras one at a time and compare.

Pool twelve cameras

Each blue row is one camera: its reading and its error bar. Press Add a camera. The teal mark is the weighted pool, the pink mark the flat average.

Illustrative toy: the forklift is at 5.00 m. The twelve error sizes run from 0.3 m to 4 m, and each reading's error is fixed in advance.

Watch camera 11, the 4 m one: the flat average jumps, the pool barely moves. The weights are right. The question of this lesson is how to keep them.

The Kalman filter of Lesson 5 stores a covariance: the spread of its belief. To fold in a camera it computes a gain, inverts a small matrix and rewrites the covariance. Each camera's step depends on the steps before it. The information filter stores the inverse of the covariance: how sure it is. Then the bookkeeping changes:

TaskKalman form (covariance)Information form
Fold in one cameragain, small inversion, rewrite the covarianceadd its information
Order of cameraseach step uses the last one's outputany order, same sum
Drop a bad camerano clean undosubtract its information
Start knowing nothinginfinite variance, no number to storeinformation 0
Move the forklift (predict)cheaptwo inversions (Chapter 4)

The road

  1. Information: one over the variance, and why it adds.
  2. Matrix and vector: the same belief as mean and covariance, inverted.
  3. The update: fusing a sensor is one addition (the hero's stacks).
  4. Predict: the step that costs two inversions.
  5. Networks: every node adds its share and gets the central answer.
  6. Showcase: a sensor network that tracks a moving target.
  7. Which form: count predicts and updates, then choose.
  8. Traps: double counting, bad inversions, a singular start.
  9. The field guide: numbers, terms, code and sources.
Twelve cameras of very different quality watch one forklift. Why is a flat average of their readings a poor pool?

Chapter 1

Information Is One Over Variance

Flip the spread of a belief into its sharpness, and see that sharpness adds

Your belief about the forklift's x has a variance: its spread, in square metres. A big variance is a vague belief, a small one a sharp belief. Call the variance σ² (sigma squared).

Now flip it. The information is one over the variance: how sharp the belief is. Lesson 3 called the same number precision. Call it Ω (capital omega).

Say it aloud

Omega equals one over sigma squared.

Ω
Omega the information: how sharp the belief is, in units of one per square metre.
1 /
one over take the reciprocal, so a small spread gives a big number.
σ²
sigma squared the variance of the belief, in square metres.
In plain words

Square the standard deviation to get the variance sigma squared. Divide 1 by it. The result is the information Omega.

With numbers

A sensor good to 2 m has sigma squared 4 m², so Omega = 1/4 = 0.25 per m². A sensor good to 5 m has 25 m² and Omega = 0.04. Five times the spread gives a twenty-fifth of the information.

Widen the bell, watch information fall

Drag the variance. The bell is the belief. The grey meter shows the variance and the purple meter the information, both on a log scale.

4.00

The meters stop at 0.05 and 50 m². Total ignorance, infinite variance, sits off the right end, where the information reaches 0.

The flip turns "I know nothing" into a usable number. Infinite variance is not a number a computer stores. Its information is 0, a clean starting value.

The flip also shows why fusion works. Sensor A reads 100 m with variance 4 m². Sensor B reads 104 m with variance 16 m². Their informations add:

Ω = 1/4 + 1/16 = 0.25 + 0.0625 = 0.3125 per m²  →  σ² = 1/0.3125 = 3.2 m²

The fused variance, 3.2 m², is smaller than both inputs. Adding information only sharpens. Chapter 3 proves the sum is the right rule and finds the fused position.

The failure: using the standard deviation where the variance belongs. Symptom: a 2 m sensor enters as 1/2 instead of 1/4, so it counts twice as much as it should. Measure: check the units; information is per square metre. Fix: square sigma first.

A belief has variance 25 m². What is its information, and what happens to the information as the variance grows without limit?

Chapter 2

The Information Matrix and Vector

Store the same belief as the mean and covariance, inverted

A forklift has an x and a y. The Kalman filter stores its belief as a mean vector μ (mu), the best guess, and a covariance matrix Σ (capital sigma). The diagonal of the covariance holds each coordinate's variance. The off-diagonal holds how the two errors move together.

The information form stores two other objects that hold the same belief. The first is the information matrix, the inverse of the covariance.

Say it aloud

Omega equals Sigma inverse.

Ω
Omega the information matrix, 2 by 2 here. A big entry means a sharp direction.
Σ
Sigma the covariance matrix of the belief, in square metres.
−1
inverse the matrix that, multiplied by Sigma, gives the identity matrix.
In plain words

Invert the covariance Sigma as a whole matrix. The result Omega is large along the directions you know well and small along the ones you do not.

With numbers

With made-up numbers: Sigma has rows 4, 2 and 2, 5. Its determinant is 4 × 5 − 2 × 2 = 16. So Omega has rows 5/16, −2/16 and −2/16, 4/16: that is 0.3125, −0.125 and −0.125, 0.25. The x entry is 0.3125, not 1/4, because the two errors move together.

The second object is the information vector: the mean, multiplied by the information matrix. Call it ξ (xi).

Say it aloud

xi equals Omega times mu.

ξ
xi the information vector, one number per coordinate, in units of one per metre.
Ω
Omega the information matrix from above.
μ
mu the mean: the best guess of the position, in metres.
In plain words

Multiply the mean mu by the information matrix Omega. To get the mean back, multiply xi by Omega inverse, which is Sigma.

With numbers

With the Omega above and mu = (10, 20) m: xi = (0.3125 × 10 − 0.125 × 20, −0.125 × 10 + 0.25 × 20) = (0.625, 3.75). Back: Sigma times xi = (4 × 0.625 + 2 × 3.75, 2 × 0.625 + 5 × 3.75) = (10, 20). The round trip loses nothing.

On its own, xi looks like noise. It is the form in which evidence adds, as Chapter 3 shows. The two descriptions match line by line:

Part of the beliefKalman formInformation form
Wheremean μξ = Ωμ
How spread or how sharpcovariance ΣΩ = Σ−1
Knowing nothingΣ infiniteΩ = 0, ξ = 0
Read the guessread μμ = Ω−1ξ (one inversion)

Shape the ellipse with information

Set the three entries of the information matrix. The teal ellipse is the belief it describes. Push one diagonal entry toward zero and watch the ellipse stretch along that axis.

0.313
0.250
−0.125

The start is the worked example above. The ellipse holds 2 standard deviations.

The failure: inverting entry by entry. Symptom: the ellipse has the wrong size and tilt whenever the two errors move together. Measure: multiply Omega by Sigma; you must get the identity matrix. Fix: invert the whole matrix, with a Cholesky routine for large ones.

A belief has covariance with rows 4, 0 and 0, 25, and mean (10, 20). What are Omega and xi?

Chapter 3

The Update Is Addition

Fold a reading into the belief by adding its information

A camera reports a reading z, with noise covariance R. A camera may see only part of the state. The measurement matrix H says which part: an edge-on camera that sees only x has H = [1 0].

The reading's own information is R inverse. H places it on the coordinates the camera sees. The update adds it to the information you hold.

Say it aloud

Omega-plus equals Omega-minus plus H-transpose, R-inverse, H.

Ω+
Omega-plus the information after the reading.
Ω−
Omega-minus the information before the reading.
HT
H-transpose H turned on its side: it carries the reading's information back onto the state.
R−1
R-inverse the reading's own information: one over its noise variance.
H
H the measurement matrix: which coordinates the camera sees.
In plain words

Turn the camera's noise R into information by inverting it. Place it on the seen coordinates with H-transpose and H. Add it to Omega-minus. The sum is Omega-plus.

With numbers

With made-up numbers: Omega-minus has diagonal 0.25 and 0.04, so the belief is good to 2 m in x and 5 m in y. An edge-on camera sees x with R = 0.25 m², so R-inverse = 4. H-transpose R-inverse H puts a 4 in the x corner only. Omega-plus has diagonal 4.25 and 0.04: x is now good to 0.49 m, and y is still 5 m.

The information vector takes the reading itself, weighted the same way.

Say it aloud

xi-plus equals xi-minus plus H-transpose, R-inverse, z.

ξ+
xi-plus the information vector after the reading.
ξ−
xi-minus the information vector before it.
HT
H-transpose places the reading on the seen coordinates.
R−1
R-inverse the reading's information, its weight.
z
z the reading, in metres.
In plain words

Weight the reading z by its information R-inverse. Place it with H-transpose. Add it to xi-minus.

With numbers

Continuing: the old mean (10, 20) m gives xi-minus = (2.5, 0.8). The camera reads z = 10.8 m, so it adds (4 × 10.8, 0) = (43.2, 0). xi-plus = (45.7, 0.8). Read back: x = 45.7 / 4.25 = 10.75 m, y = 0.8 / 0.04 = 20 m.

Check it against Lesson 3 in one dimension, where H = 1. Start from knowing nothing: Omega = 0, xi = 0. Add sensor A (100 m, 4 m²) and sensor B (104 m, 16 m²):

Ω = 0 + 0.25 + 0.0625 = 0.3125  ·  ξ = 0 + 25 + 6.5 = 31.5  →  x = 31.5 / 0.3125 = 100.8 m, σ² = 3.2 m²

That is the inverse-variance fuse of Lesson 3, number for number. Addition does not care about order, and subtracting a reading's two terms removes it exactly.

Stack the information

Press Add a sensor. Each purple block is one sensor's information; the stack height is the sum. The teal bell is the fused belief. Remove last takes the top block off.

Illustrative toy: the truth is 100 m. Sensors A and B are the worked example; the other four are invented.

The failure: a noise R that is too small. Symptom: the estimate jumps to one sensor and ignores the rest. Measure: log the gaps between readings and estimates; their spread should match HSHT + R, with S the covariance. Fix: set R from logged data.

Build the fuse yourself below: convert, add, convert back.

Starting from Omega = 0, sensor A brings information 0.25 (vector 25) and sensor B brings 0.0625 (vector 6.5). What is the fused belief?

Chapter 4

Predict Costs Two Inversions

Pay for the cheap update with an expensive motion step

Between readings the forklift moves. The predict step pushes the belief through the motion model F, the matrix that moves the state one step. It then adds the process noise Q: the uncertainty the motion adds, as a covariance. In the Kalman form that is one line, Σ− = FΣFT + Q: multiply, then add.

The information form has no such shortcut. Q says "the forklift may have drifted 1 m", which is a covariance. To add it you must leave information form, add, and come back.

Say it aloud

Omega-minus equals the inverse of: F, Omega-inverse, F-transpose, plus Q.

Ω−
Omega-minus the predicted information, before the next reading.
F
F the motion model. Here F = 1: the model expects the forklift to stay put.
Ω−1
Omega-inverse the current covariance: inversion number one.
FT
F-transpose F turned on its side, so the covariance moves on both sides.
Q
Q the process noise covariance, in square metres per step.
( … )−1
the inverse of inversion number two, back to information.
In plain words

Invert Omega to get the covariance. Move it with F and add Q. Invert the result to get Omega-minus.

With numbers

With made-up numbers in one dimension: Omega = 0.25, F = 1, Q = 1 m². Invert: 1 / 0.25 = 4 m². Add Q: 4 + 1 = 5 m². Invert back: 1 / 5 = 0.2. The information fell from 0.25 to 0.2.

The information vector follows the mean: ξ− = Ω−FΩ−1ξ. With a mean of 100 m above, xi goes from 25 to 0.2 × 100 = 20.

Drain and refill

Press Predict a few times: the purple bars fall. Press Add a reading: they jump back up. Raise Q and the drain gets steeper.

1.0

Illustrative toy in one dimension: F = 1, each reading has variance 4 m² (information 0.25). In one dimension an inversion is one division; in n dimensions it is about n³ multiplies.

Inverting an n by n matrix costs about n³ multiplies. Two per predict is the bill for the cheap update. The two forms are mirror images:

StepKalman formInformation form
Predictmultiply by F, add Qinvert, move, add Q, invert
Update, per readinggain, small inversion, rewrite Σadd two terms

The failure: leaving Q at zero. Symptom: the information never drains, the filter grows sure of itself and stops following the forklift. Measure: plot the claimed sigma against the real error on a logged run. Fix: set Q from how far the forklift can move between steps.

Why does the predict step cost two inversions in the information form?

Chapter 5

Every Node Adds Its Share

Pool a sensor network by summing, and get the central answer

Lesson 2 described decentralized fusion: each sensor node has its own processor, and no central computer collects the raw data. The hard question is how the nodes pool their estimates and still get the answer a central filter would.

In information form, each node ships its new information: the two terms of Chapter 3. Any node, or a tally, adds them. Call the shared starting information Ω0 and node i's new information Ωi.

Say it aloud

Omega equals Omega-zero plus the sum over i of Omega-i.

Ω
Omega the pooled information of the whole network.
Ω0
Omega-zero the shared prior: what every node knew before, counted once.
Σi
the sum over i add one term for each node, in any order.
Ωi
Omega-i node i's new information, H-transpose R-inverse H for its own reading.
In plain words

Start from the prior Omega-zero once. Add each node's new information Omega-i. Do the same with the information vectors, then convert back.

With numbers

With made-up numbers, no prior (Omega-zero = 0), and three nodes reading x: 50.0 m with variance 1, 52.0 m with 4, 47.0 m with 10. Omega = 1 + 0.25 + 0.1 = 1.35. xi = 50 + 13 + 4.7 = 67.7. So the variance is 1 / 1.35 = 0.741 m² and x = 67.7 / 1.35 = 50.15 m.

The pooled variance, 0.741 m², beats the best node's 1 m². The estimate leans toward the sharp node and barely hears the vague one. A central filter given all three readings computes the same sum, so the network loses nothing (Rao and Durrant-Whyte, 1991). Lose a node, and its term drops out. Add one, and the sum has one more term.

Pool three nodes

Switch nodes on and off and press Shuffle order: the sum does not change. Then switch on Ship the prior too, the classic mistake, and compare with the central answer.

Illustrative toy: the three nodes of the worked example, plus a shared prior of information 0.2 centred on 49 m.

The failure: each node ships its whole posterior, prior included. Symptom: the pool claims more certainty than the evidence gives; with three nodes the pool counts the prior three times. Measure: compare the pool with Omega-zero plus the nodes' new terms. Fix: each node subtracts the prior before it ships.

Pool five two-dimensional nodes yourself below, then invert once.

Three independent nodes ship informations 1.0, 0.25 and 0.1 (vectors 50, 13 and 4.7). How does the network get the central answer?

Chapter 6

Showcase: A Network That Tightens by Addition

Run the whole filter: predict, add each node, and check it against the Kalman form

Five nodes surround a moving target. Each sees well in one direction only: its faint blue ellipse is thin across its line of sight and long along it. The filter starts from a weak prior, then on each step it predicts and adds every active node. The read-out runs the Kalman form beside it on the same readings.

Track with a sensor network

Toggle nodes and watch the teal ellipse. Press Run: each step the ellipse grows (predict) and shrinks again (the additions).

Illustrative toy: nodes 1 to 4 see 0.4 m across their line of sight and 2 m along it. Node 5 sees 1.2 m and 3 m. The prior is information 0.01 per m². Each step adds Q = 0.08 m². The ellipses hold 2 standard deviations.

Try these five moves:

  1. Node 1 alone. A thin horizontal sliver: the filter knows x, not y.
  2. Add node 2. The sliver snaps to a small round blob. Each node adds information where the other was blind.
  3. Add nodes 3 and 4. The blob shrinks again. A node never makes it grow.
  4. Switch node 1 off. Its term leaves the sum; the ellipse loosens a little in x.
  5. Press Run. Predict grows the ellipse, the additions shrink it, on every step.

Watch the last line of the read-out: the Kalman form agrees to under 10−12 m, rounding error. The order of the additions never matters. Node 5 adds the least, because its information is small.

Add two blind directions into one sharp joint below.

Node 1 sees x well and y badly; node 2 sees y well and x badly. What does the fused ellipse look like with both on?

Chapter 7

Which Form to Use

Count predicts and updates, then pick the form whose cheap step you do most

Both forms give the same numbers. You pick one for cost and for the shape of the system. Count multiplies for a state of n numbers, where each sensor report holds d numbers:

StepKalman formInformation form
One predictabout 2n³about 4n³ (two inversions and the move)
One sensor reportabout 2n²dabout n²d

With m reports per predict, set the two totals equal: 2n³ + 2n²dm = 4n³ + n²dm. The information form wins when m is above 2n/d. For a forklift state of 6 numbers and cameras that report x and y, that is more than 6 reports per predict.

Count the multiplies

Set the state size and the reports per predict. Yellow is the predict part of each bar, blue the report part.

6
12

Leading terms only, each report has d = 2 numbers, and the Kalman form takes reports one at a time. Real costs depend on the library and on sparsity, so treat the crossover as a guide.

Real systems follow the count:

SystemFormWhy
Warehouse camera gridinformation12 reports per slow step; cameras join and drop
Radar network, track-to-track fusioninformationno central computer; each radar adds its track
SLAM with many landmarksinformation (SEIF)the information matrix is nearly sparse
Racing drone, one IMU at 1,000 HzKalmanmany predicts, one sensor

SLAM needs a word. Its state holds the robot and every landmark. A landmark reading adds information only to the entries that link the robot to that landmark. So most entries of the information matrix stay near zero, while the covariance fills in. The Sparse Extended Information Filter keeps the matrix sparse (Thrun, Burgard and Fox, Chapter 12).

The failure: the information form on a fast loop with one sensor. Symptom: the profiler shows the predict step eating the time budget. Measure: count predicts and reports per second. Fix: use the Kalman form for that loop.

A slow forklift, 12 cameras each reporting x and y, a state of 6 numbers, and cameras added every month. Which form?

Chapter 8

Three Traps

Catch double counting, a bad inversion and a singular start before they ship

Every plus sign in the information form is a promise: this term is new, independent evidence. Break the promise and the filter lies.

The classic route is the echo. Node A sends its estimate to node B. B fuses it and sends the result back. A adds it, not knowing that its own reading is inside. The same evidence is now in the sum twice.

This is double counting, also called data incest. Say one reading has variance σ², and the network adds it k times.

Say it aloud

sigma-squared-claimed equals sigma squared over k.

σ²claimed
sigma-squared-claimed the variance the filter reports, in square metres.
σ²
sigma squared the real variance of the one reading.
k
k how many times the network adds the same reading.
In plain words

Adding the same information k times multiplies it by k. So the claimed variance shrinks by k, while the real error stays sigma squared.

With numbers

With made-up numbers: sigma squared is 4 m² and the echo adds the reading twice, so k = 2. The claim is 4 / 2 = 2 m², a sigma of 1.41 m, while the real sigma is 2 m. About 16% of real errors then fall outside the claimed 2-sigma band, where 5% should.

Count the same reading twice

Each dot is the real error of one run. The shaded band is the 2-sigma band the filter claims: teal when honest, red when too narrow. Slide the copies up and count the dots outside.

1

Illustrative toy: 200 runs with a real sigma of 2 m, drawn from a fixed seed. The NEES is the average of error squared over claimed variance; 1 is honest.

An overconfident filter is worse than a vague one: it rejects good readings that disagree with its false precision. The three traps:

TrapSymptomMeasureFix
Double countingtight ellipse, large real errorsNEES well above 1 on logged runstrack where each term came from; ship only new information; use covariance intersection (Lesson 11) for correlated sources
Ill-conditioned predictnumbers drift, then blow upcondition number of the matrices you invertCholesky inversion; add a tiny multiple of the identity
Singular startreading the mean throws an errorsmallest eigenvalue of Omegawait until a sensor sees every direction, or add a weak prior

The singular start comes from the zero prior. With Omega = 0, or with only an edge-on camera, some direction has no information yet, and Omega has no inverse. That is honest: the filter does not know. Code must check before it inverts.

A node's estimate echoes around the network and gets added again. The reported ellipse shrinks, but the real errors stay large. Which trap, and which fix?

Chapter 9

The Field Guide

Keep the numbers, the terms, the checks and the core code of the lesson on one page

The information filter stores Omega, the inverse covariance, and xi, Omega times the mean. A reading adds its information: one addition, any order, and subtraction undoes it. Predict pays for this with two inversions. A network of independent nodes adds its terms and gets the central answer.

The numbers

WhatNumberWhy it matters
Information of a 2 m sensor1 / 4 = 0.25 per m²square sigma first
Two sensors, 1-D0.25 + 0.0625 = 0.3125; 100.8 m, 3.2 m²equals the Lesson 3 fuse
Correlated 2 by 2 inverseΩ xx = 0.3125, not 0.25invert the whole matrix
Edge-on camera, R = 0.25adds 4 to x only; x from 2 m to 0.49 mH places the information
One predict, Q = 10.25 → 4 → 5 → 0.2two inversions
Three nodesΩ 1.35, ξ 67.7; 50.15 m, 0.741 m²beats the best node
Crossoverm above 2n/d reports per predictpicks the form
Reading added twiceclaims 2 m² for 4 m²; 16% outside 2 sigmadouble counting

The terms

TermMeaning
InformationOne over the variance: how sharp a belief is.
Information matrixThe inverse of the covariance matrix, Omega.
Information vectorOmega times the mean, xi.
Measurement matrixH: which coordinates a sensor sees.
Process noiseQ: the doubt one motion step adds, as a covariance.
Decentralized fusionNodes fuse among themselves with no central computer.
Double countingThe same evidence added more than once; the filter claims too much.
NEESAverage of error squared over claimed variance; 1 is honest.

The checklist

  1. Count predicts and reports per second. Pick the form whose cheap step you do most.
  2. Square each sigma before you invert it.
  3. Ship only new information; count the prior once.
  4. Check Omega's smallest eigenvalue before you read the mean.
  5. Invert with Cholesky, and watch the condition number.
  6. Run the NEES on logged data.

The core as code

pythonimport numpy as np

def update(Om, xi, H, R, z):                 # a reading ADDS its information
    Ri = np.linalg.inv(R)                       # the sensor's small noise matrix
    return Om + H.T @ Ri @ H, xi + H.T @ Ri @ z

def predict(Om, xi, F, Q):                  # two inversions
    Sig = np.linalg.inv(Om); mu = Sig @ xi
    Om_p = np.linalg.inv(F @ Sig @ F.T + Q)
    return Om_p, Om_p @ (F @ mu)

def read(Om, xi):                            # only when someone asks
    assert np.linalg.eigvalsh(Om).min() > 1e-9, "not every direction seen yet"
    Sig = np.linalg.inv(Om)
    return Sig @ xi, Sig

Om, xi = np.diag([0.25, 0.04]), np.array([2.5, 0.8])        # mean (10, 20)
Om, xi = update(Om, xi, np.array([[1., 0]]), np.array([[0.25]]), np.array([10.8]))
mu, Sig = read(Om, xi)                                     # (10.75, 20.0)

Keep going

The takeaway. Store how sure you are, and every independent sensor becomes one addition. Pay for it at predict time, and never add the same evidence twice.
A colleague says the information filter is a faster Kalman filter, so it is always better. What is the correction?

Now press Present or Teach. Explain from memory why information adds, the update with H and R, the two inversions of predict, and the echo that double counts. Then go back to the six cameras, switch on cameras 1 and 2, and say why the ellipse turns round.

Sources

  1. S. Thrun, W. Burgard and D. Fox, Probabilistic Robotics, MIT Press, 2005. Chapter 3 derives the information filter; Chapter 12 covers the Sparse Extended Information Filter. probabilistic-robotics.org
  2. B. S. Rao and H. F. Durrant-Whyte, "Fully decentralised algorithm for multisensor Kalman filtering," IEE Proceedings D, 1991.
  3. P. S. Maybeck, Stochastic Models, Estimation, and Control, Vol. 1, Academic Press, 1979.
  4. A. G. O. Mutambara, Decentralized Estimation and Control for Multisensor Systems, CRC Press, 1998.
Sensor Fusion: Classical to Modern · Lesson 9: The Information Filter
Next: The Particle Filter · Back to Gleams